Calculators
Backup for outages
Tick the devices you need during an outage and how many hours it lasts — and right away the battery capacity, the inverter power and how many panels bring that energy back in a day.
What you get
- —energy for the outage
- —nominal battery capacity
- —modules
- —inverter
- —power / surge
- —panels to recharge in winter
- —battery with inverter
- —generator fuel for the same
What the calculation assumes
- LFP battery: 90% of the capacity is usable, inverter efficiency 92%.
- Module — 5.12 kWh (51.2 V, 100 Ah).
- Inverter — with a 25% margin for the starting currents of pumps and compressors.
- Recharge — how many kW of panels bring back the energy of one outage in a day of the darkest month.
- Generator for comparison: a diesel uses 0.30 l per kWh at full load and 0.45 at a quarter (dealer’s table); the top of the range allows for low load and petrol, whose consumption the source does not check.
Sun and climate: PVGIS 5.3, Joint Research Centre of the European Commission — PVGIS © European Communities, 2001–2026.
Do the numbers add up?
Send them with a request — we’ll check on site and draw up an estimate.